Skip to content
CSIL Central Safety Inspections Nottingham · East Midlands 07971 571 275 Request a quote

Independent competent person

Click here to leave us a Google review

LOLER, PUWER, WAHR & Air Receiver Inspections in the East Midlands

Statutory thorough examinations and compliance inspections for businesses across the East Midlands. One engineer surveyor, on site, start to finish — with certification issued the same day.

Request a quote Call 07971 571 275
Engineer surveyor carrying out a LOLER thorough examination of a forklift truck on site in the East Midlands

Fig. 01 — Thorough examination in progress

LOLER 1998

Lifting equipment

PUWER 1998

Machinery safety

WAHR 2005

Height safety kit

PSSR 2000

Air receivers

Fully insured

Public liability and professional indemnity insurance in place; certificates available on request.

24-hour response

Quote requests and enquiries answered within one working day, every time.

Same-day certificates

Reports and certification issued the day of the visit, not a fortnight later.

Emergency attendance

Same-week and emergency inspections where equipment is out of service or overdue.

01 — Services

Four statutory regimes, one visit

Every inspection ends with a written report and certification you can hand straight to an auditor, insurer or client.

LOLER 1998

01

LOLER lifting equipment

Thorough examination and certification of lifting equipment and accessories, with a written report you can produce on demand.

  • Forklifts
  • Vehicle lifts
  • Cranes & gantries
  • Chain blocks
  • Slings & chains
  • MEWPs
  • and more

Interval — 6 or 12 monthsRead more →

PUWER 1998

02

PUWER machinery safety

Compliance inspection of workplace machinery: guarding, emergency stops, controls, condition and maintenance, with risk-based recommendations.

  • CNC machinery
  • Workshop equipment
  • Production lines
  • Woodworking machines
  • Presses
  • General plant
  • and more

Interval — Risk basedRead more →

WAHR 2005

03

Working at height equipment

Inspection of height safety equipment to the Work at Height Regulations 2005, including guidance on pre-use checks for your users.

  • Safety harnesses
  • Lanyards
  • Fall arrest systems
  • Anchor points
  • Ladders
  • Podiums
  • and more

Interval — 6 monthsRead more →

PSSR 2000

04

Air receivers & pressure systems

Examination of air receivers, compressors and associated pipework, with support drawing up or reviewing a Written Scheme of Examination.

  • Air receivers
  • Compressors
  • Pressure vessels
  • Pipework
  • Safety valves
  • Written schemes
  • and more

Interval — Per written schemeRead more →

02 — Equipment A–Z

Which regulation applies to your kit?

EquipmentRegulationInterval
Air receiver PSSR 2000 Per written scheme Anchor point / eyebolt WAHR 2005 12 months Bandsaw PUWER 1998 Risk based Beam trolley LOLER 1998 12 months Chain block / hoist LOLER 1998 12 months Chain sling LOLER 1998 6 months CNC machine PUWER 1998 Risk based Compressor PSSR 2000 Per written scheme Crane (overhead / gantry) LOLER 1998 12 months Fall arrest block WAHR 2005 6 months Forklift truck LOLER 1998 12 months Forklift attachment LOLER 1998 6 months Guillotine / press PUWER 1998 Risk based Harness WAHR 2005 6 months Jib crane LOLER 1998 12 months Ladder / step ladder WAHR 2005 6 months Lanyard WAHR 2005 6 months Lifting beam / spreader LOLER 1998 6 months MEWP / cherry picker LOLER 1998 6 months Passenger lift LOLER 1998 6 months Pipework (pressure) PSSR 2000 Per written scheme Podium / mobile tower WAHR 2005 6 months Pressure vessel PSSR 2000 Per written scheme Round sling / webbing LOLER 1998 6 months Safety valve PSSR 2000 Per written scheme Scissor lift LOLER 1998 6 months Shackle / hook LOLER 1998 6 months Vehicle lift (2 / 4 post) LOLER 1998 6 months Woodworking machine PUWER 1998 Risk based Workshop crane / engine hoist LOLER 1998 12 months
No equipment matches that search — call 07971 571 275 and we'll tell you what applies.

Intervals shown are statutory minimums. Where an examination scheme or Written Scheme of Examination is in place, that scheme sets the frequency.

Andrew Shore, engineer surveyor and independent competent person, on site

03 — The competent person

Andrew Shore, Engineer Surveyor

The regulations do not ask for a company. They ask for a competent person: someone with the practical knowledge, engineering experience and independence to examine equipment properly and report on it accurately. That requirement is the whole basis of this business.

You deal directly with the engineer surveyor who does the work — no call centre, no rotating inspectors, and no report written by someone who never saw the machine.

Engineer surveyor

A time-served engineering background behind every examination — not a checklist operator.

Genuinely independent

Not tied to an insurer, hire company or equipment supplier. The report says what the kit is like.

Fully insured

Public liability and professional indemnity cover; a limited company registered in England & Wales.

One point of contact

The same inspector every visit, on a mobile, who knows your site and your equipment.

Same-day certification

Reports and certificates issued the day of the visit, in a format auditors accept.

Flexible attendance

Early starts, late finishes and shutdown periods worked around so production keeps running.

Qualifications & insurance →

04 — Areas covered

Based in Nottingham, working across the East Midlands

We provide LOLER, PUWER, working at height and air receiver inspections in Derby, Leicester, Mansfield, Lincoln and across Nottinghamshire — for construction, warehousing, manufacturing, automotive workshops, facilities management and property management companies.

Nottingham

Base

Derby

All 4 services

Leicester

All 4 services

Mansfield

All 4 services

Lincoln

All 4 services

Chesterfield

Covered

Loughborough

Covered

Newark

Covered

Worksop

Covered

All areas

Full list

05 — Questions

Compliance, in plain English

A LOLER inspection is a thorough examination of lifting equipment carried out by a competent person to confirm it is safe to use. You receive a written report of thorough examination recording what was examined, any defects found and the date the next examination is due.

Every 6 months for equipment used to lift people and for lifting accessories, and every 12 months for other lifting equipment — unless an examination scheme drawn up by a competent person specifies different intervals.

PUWER covers all work equipment in the workplace: that it is suitable for the job, safe to use, properly maintained, guarded, and operated by people who have been trained. Unlike LOLER there is no fixed interval — inspection frequency is based on risk and use.

Yes. Under the Pressure Systems Safety Regulations 2000 a pressure system including an air receiver must be examined in accordance with a Written Scheme of Examination. Without a scheme in place, the system should not be operated.

A document, drawn up or certified by a competent person, that identifies which parts of a pressure system are examined, the nature of each examination, the intervals between them and any measures needed to prepare the system safely.

Yes, where that person is competent for both. In practice one visit can cover lifting equipment, machinery, height safety equipment and air receivers together — less downtime for you and one consistent set of paperwork.

You get a clear verbal briefing on site and a written report identifying the defect, whether it presents an immediate or imminent danger, and what has to be done. Equipment with a serious defect is taken out of service until it is repaired and re-examined.

All questions →

06 — Guides

Written by the engineer, not a copywriter

LOLER How often does lifting equipment need inspecting? The 6-month and 12-month rules, and when an examination scheme changes them. Comparison PUWER vs LOLER — what is the difference? Two regulations, two duties, and the equipment that falls under both. PSSR What is a Written Scheme of Examination? What the scheme has to cover, who writes it, and why you cannot run without one. Height Do harnesses need inspecting every 6 months? Detailed inspection intervals, pre-use checks and the records you must keep.

Nottingham · Derby · Leicester · Mansfield · Lincoln

Book an inspection or ask a question

Quotes answered within 24 hours. Same-week and emergency attendance available where equipment is out of service.

Call now Request a quote

Cookies on this site